Home    >    Products    >    PD Flow Meters    >    Low Flow PD Meter


    Low Flow PD Meter  
 
Flow Technology Low-Flow Trickle Meter
 
Only two moving parts 1000 PSI
Stainless steel case, carbide shafts
Up to 100:1 turndown
3/8" NPT connections
Non-intrusive sensor
Easy installation and maintenance
Wide range of applications
Handles pulsating flow systems Ideal for additive injection

     Operating Temperature:

         -20°F to +450°F; (-29°C to +232°C)
     Operating Pressure: 1,000 psig (6.89 MPa)
     Turndown Ratio:
        Low-viscosity fluids 10:1 standard (1.0 to 3.0 cP)
        Medium-viscosity fluids 100:1 standard (>3.0 cP)
        High-viscosity fluids 100:1 standard (>3.0 cP)
     Repeatability: ±0.05% of rate on medium/high-viscosity fluids
     Accuracy (Linearity):
   ±0.5% of rate over upper 80% of full span typical (Medium/high-viscosity fluids  )
   Up to ±0.1% of rate over full turndown range (With enhanced signal conditioning)
     Flow Rate:
   Minimum 0.005 GPM (0.019 L/min)*
   Maximum 0.5 GPM (1.9 L/min)*
     Weight 2.5 lbs (1.1 kg)
     Output (Refer to individual product sheets for complete specifications)
     Sensors (1 required per meter)
        Surface Reference Sensor: 7-30 VDC square-wave pulse depending on supply voltage, 3-wire
     Materials of Construction
       Cover(s) 316 stainless steel, standard
   Shafts Tungsten Carbide
   Impellers 440C, Hardened
   O-Rings Viton® or Teflon® standard
   Bolts Black-Oxide Grade 8 standard
      
        Note: High Strength Corrosion-Resistant A-286 Stainless Steel bolts are available.
 
 
TrickleMeter LowFlow PD Flow Meter.PDF