Home    >    Products    >    Mass Flow Meters    >    Flow & Temp. Mass Meter


    Flow & Temp. Mass Meter  
 
FOX Model FT2 Flow & Temperature Thermal Mass Transmitter
 
Measures gas flow rate in SCFM, NM3/hr, Lbs/hr, Kg/hr, & many more
Wide measurement range; 100 to 1 turndown
Measures process gas temperature
4 to 20 mA for flow rate & temperature; pulse output for flow/total
RS232 for connecting a Palm Handheld or computer; RS422/RS485-Modbus, Profibus-DP, DeviceNet or Ethernet Modbus TCP
Insertion and In-line models
Welded, 316 SS sensor construction; Hastelloy C276 optional
Microprocessor based, field programmable electronics
On-board 2 line x 16 character, backlit display with configuration panel to view/set readings and parameters
Palm Handheld Terminal available to view/set readings and parameters
NIST traceable calibration
Low-end sensitivity for leak detection
Negligible pressure drop
No moving parts design
FM (U.S.) & FMc (CANADIAN) approved for Class I, II, III, Division 2, Groups A, B, C, D, E, F, G T4A hazardous locations. NEMA 4X and CE approved

     Accuracy: ±1.0% of reading + 0.2% of full scale
     Repeatability: ±0.2% of full scale
     Response Time: 0.9 seconds (One time constant)
     Temperature Accuracy: ± 1.8° F (± 1.0° C) over -40 to
250° F (-40 to 121° C); ± 3.6° F (± 2.0° C) over 250 to
650°F (121 to 343°C). Min. velocity 60 SFPM
     Units of Measurement: SCFM, SCFH, NM3/hr,
NM3/min, Kg/hr, Kg/min, Kg/sec, Lbs/d, Lbs/hr,
Lbs/min, Lbs/sec, NLPH, NLPM, SLPM, SMPS,
NMPS, SFPM, MMSCFD, MMSCFM, SM3/hr
     Flow Rates: Insertion Flowmeters, 0 to 32,000 SFPM (0-163 NMPS) - Air at 70F & 1ATM
     Max. Gas Pressure, at 100° F (38° C):
           Insertion Flowmeter: 500 psig (34.5 barg)
           In-Line (1/4" through 6"): NPT 500 psig (34.5 barg) 150# flange 230 psig (16 barg)
Temperature:
          Sensor -40 to 250° F (-40 to 121° C)
          HS Sensor 32 to 400° F (0 to 204° C)
          HT Sensor: 32 to 650° F (0 to 343° C)
          Enclosure -40 to 131° F (-40 to 55° C)
     Input Power: 24 VDC, ±10%, 0.75 amp standard; 85 to 250VAC 50/60Hz, 20 watts optional
     Output:
          Two isolated 4 to 20 mA outputs (1 for flow & 1 for temperature); isolated pulse output 0 to 100Hz, 10 volts p/p for flow
          RS232 for connecting a Palm Handheld or computer
          RS422/ RS485-Modbus, Profibus-DP, DeviceNet or Ethernet Modbus TCP
     Sensor: 316 SS standard, Hastelloy C276 optional
     Enclosure: FM (U.S.) & FMc (CANADIAN) approved for Class I, II, III, Division 2, Groups A, B, C, D, E, F, G, T4A hazardous locations. NEMA 4X and CE approved. Options Remote NEMA 4X electronics enclosure with explosion proof sensor j-box
     Flowmeters Dimension: Probe diameter: 1/2"
 
 
FT2 Flow Temperature Thermal Mass Transmitter.PDF
FT2 Manual.PDF